The incorrect statement regarding generators is

The incorrect statement regarding generators is Back pitch and front pitch are both odd and approximately equal to the pole pitch Compensating winding in a machine helps in commutation Equalizing bus bars are used with parallel running of shunt generators In a D. C. generator interpoles winding is connected in series with the armature winding … Read more

A series generator can self-excite

A series generator can self-excite Irrespective of the value of load current Only if the load current is not zero Only if the load current is zero None of these Correct answer: 2. Only if the load current is not zero Visit Electrical Engineering MCQ here for more

If an electrical generator fails to build up the probable cause could not be

If an electrical generator fails to build up the probable cause could not be Faulty shunt connections tending to reduce the residual magnetism Field resistance less than the critical resistance Imperfect brush contact No residual magnetism in the generator Correct answer: 2. Field resistance less than the critical resistance Visit Electrical Engineering MCQ here for … Read more